Abstract
This work addresses the modelling of the effects of maintenance on the degradation of an electric power plant component. This is done within a modelling framework previously proposed by the authors, of which the distinguishing feature is the characterization of the component living conditions by influencing factors (IFs), i.e. conditioning aspects of the component life that influence its degradation. The original fuzzy logic-based modelling framework includes maintenance as an IF; this requires one to jointly model its effects on the component degradation together with those of the other influencing factors. This may not come natural to the experts who are requested to provide the if-then linguistic rules at the basis of the fuzzy model linking the IFs with the component degradation state. An alternative modelling approach is proposed in this work, which does not consider maintenance as an IF that directly impacts on the degradation but as an external action that affects the state of the other IFs. By way of an example regarding the propagation of a crack in a water-feeding turbo-pump of a nuclear power plant, the approach is shown to properly model the maintenance actions based on information that can be more easily elicited from experts.
Domains
OtherOrigin | Files produced by the author(s) |
---|