<TEI xmlns="http://www.tei-c.org/ns/1.0" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:hal="http://hal.archives-ouvertes.fr/" xmlns:gml="http://www.opengis.net/gml/3.3/" xmlns:gmlce="http://www.opengis.net/gml/3.3/ce" version="1.1" xsi:schemaLocation="http://www.tei-c.org/ns/1.0 http://api.archives-ouvertes.fr/documents/aofr-sword.xsd">
  <teiHeader>
    <fileDesc>
      <titleStmt>
        <title>HAL TEI export of hal-00761552</title>
      </titleStmt>
      <publicationStmt>
        <distributor>CCSD</distributor>
        <availability status="restricted">
          <licence target="https://creativecommons.org/publicdomain/zero/1.0/">CC0 1.0 - Universal</licence>
        </availability>
        <date when="2026-05-11T00:59:16+02:00"/>
      </publicationStmt>
      <sourceDesc>
        <p part="N">HAL API Platform</p>
      </sourceDesc>
    </fileDesc>
  </teiHeader>
  <text>
    <body>
      <listBibl>
        <biblFull>
          <titleStmt>
            <title xml:lang="en">Modelling of flawed riveted structures for EC inspection in aeronautics</title>
            <author role="aut">
              <persName>
                <forename type="first">S.</forename>
                <surname>Paillard</surname>
              </persName>
              <email type="md5">9758f7ecb8ffa1e7c3510dceca110eb7</email>
              <email type="domain">cea.fr</email>
              <idno type="idhal" notation="string">severine-paillard</idno>
              <idno type="idhal" notation="numeric">1356793</idno>
              <idno type="halauthorid" notation="string">174020-1356793</idno>
            </author>
            <author role="aut">
              <persName>
                <forename type="first">G.</forename>
                <surname>Pichenot</surname>
              </persName>
              <idno type="halauthorid">92064-0</idno>
              <affiliation ref="#struct-40217"/>
            </author>
            <author role="aut">
              <persName>
                <forename type="first">Yahya</forename>
                <surname>Choua</surname>
              </persName>
              <idno type="halauthorid">373625-0</idno>
              <affiliation ref="#struct-1290"/>
            </author>
            <author role="aut">
              <persName>
                <forename type="first">Yann</forename>
                <surname>Le Bihan</surname>
              </persName>
              <email type="md5">e84f86cd6222fa32dde9dc4de7a1ea66</email>
              <email type="domain">geeps.centralesupelec.fr</email>
              <idno type="idhal" notation="string">yann-le-bihan</idno>
              <idno type="idhal" notation="numeric">6436</idno>
              <idno type="halauthorid" notation="string">7402-6436</idno>
              <idno type="IDREF">https://www.idref.fr/095667075</idno>
              <idno type="ORCID">https://orcid.org/0000-0001-5563-9192</idno>
              <affiliation ref="#struct-1290"/>
            </author>
            <author role="aut">
              <persName>
                <forename type="first">Marc</forename>
                <surname>Lambert</surname>
              </persName>
              <email type="md5">6b1af8bef5ef916c396b6052bdff5219</email>
              <email type="domain">geeps.centralesupelec.fr</email>
              <idno type="idhal" notation="string">marc-lambert</idno>
              <idno type="idhal" notation="numeric">2036</idno>
              <idno type="halauthorid" notation="string">27088-2036</idno>
              <idno type="ARXIV">https://arxiv.org/a/lambert_m_1</idno>
              <idno type="RESEARCHERID">http://www.researcherid.com/rid/AAX-3271-2020</idno>
              <idno type="IDREF">https://www.idref.fr/12429443X</idno>
              <idno type="ORCID">https://orcid.org/0000-0003-0519-8477</idno>
              <idno type="GOOGLE SCHOLAR">https://scholar.google.fr/citations?user=jx5l0-AAAAAJ&amp;hl=fr</idno>
              <idno type="RESEARCHERID">http://www.researcherid.com/rid/http://www.researcherid.com/rid/AAX-3271-2020</idno>
              <affiliation ref="#struct-396671"/>
            </author>
            <author role="aut">
              <persName>
                <forename type="first">Hubert</forename>
                <surname>Voillaume</surname>
              </persName>
              <idno type="halauthorid">381947-0</idno>
              <affiliation ref="#struct-88974"/>
            </author>
            <author role="aut">
              <persName>
                <forename type="first">N.</forename>
                <surname>Dominguez</surname>
              </persName>
              <idno type="halauthorid">179941-0</idno>
            </author>
            <editor role="depositor">
              <persName>
                <forename>Thierry</forename>
                <surname>Leblanc</surname>
              </persName>
              <email type="md5">959ffebc7c8f61b35491c535a90fef3a</email>
              <email type="domain">centralesupelec.fr</email>
            </editor>
          </titleStmt>
          <editionStmt>
            <edition n="v1" type="current">
              <date type="whenSubmitted">2012-12-05 16:42:17</date>
              <date type="whenWritten">2008</date>
              <date type="whenModified">2024-09-03 11:16:05</date>
              <date type="whenReleased">2012-12-07 10:51:35</date>
              <date type="whenProduced">2008</date>
            </edition>
            <respStmt>
              <resp>contributor</resp>
              <name key="124067">
                <persName>
                  <forename>Thierry</forename>
                  <surname>Leblanc</surname>
                </persName>
                <email type="md5">959ffebc7c8f61b35491c535a90fef3a</email>
                <email type="domain">centralesupelec.fr</email>
              </name>
            </respStmt>
          </editionStmt>
          <publicationStmt>
            <distributor>CCSD</distributor>
            <idno type="halId">hal-00761552</idno>
            <idno type="halUri">https://centralesupelec.hal.science/hal-00761552</idno>
            <idno type="halBibtex">paillard:hal-00761552</idno>
            <idno type="halRefHtml">A. Tamburrino; Y. Melikhov; Z. Chen; L. Upda. &lt;i&gt;Electromagnetic Non–Destructive Evaluation&lt;/i&gt;, 31, IOS Press, pp.217-224, 2008, Studies in Applied Electromagnetics and Mechanics, 978-1-58603-896-0. &lt;a target="_blank" href="https://dx.doi.org/10.3233/978-1-58603-896-0-217"&gt;&amp;#x27E8;10.3233/978-1-58603-896-0-217&amp;#x27E9;&lt;/a&gt;</idno>
            <idno type="halRef">A. Tamburrino; Y. Melikhov; Z. Chen; L. Upda. Electromagnetic Non–Destructive Evaluation, 31, IOS Press, pp.217-224, 2008, Studies in Applied Electromagnetics and Mechanics, 978-1-58603-896-0. &amp;#x27E8;10.3233/978-1-58603-896-0-217&amp;#x27E9;</idno>
            <availability status="restricted"/>
          </publicationStmt>
          <seriesStmt>
            <idno type="stamp" n="CEA">CEA - Commissariat à l'énergie atomique</idno>
            <idno type="stamp" n="SUPELEC">SUPELEC</idno>
            <idno type="stamp" n="UPMC" corresp="SORBONNE-UNIVERSITE">Université Pierre et Marie Curie</idno>
            <idno type="stamp" n="EC-PARIS">Ecole Centrale Paris</idno>
            <idno type="stamp" n="CNRS">CNRS - Centre national de la recherche scientifique</idno>
            <idno type="stamp" n="UNIV-PSUD">Université Paris Sud - Paris XI</idno>
            <idno type="stamp" n="SUP_LSS">Laboratoire des Signaux et Systèmes</idno>
            <idno type="stamp" n="SUP_LGEP" corresp="SUPELEC">Laboratoire de génie électrique de Paris</idno>
            <idno type="stamp" n="SUP_ICHAMS" corresp="SUPELEC">ICHAMS - Equipe Interaction Champs - Matériaux et Structures</idno>
            <idno type="stamp" n="SUP_EMG" corresp="SUPELEC">EMG - Département Electromagnétisme</idno>
            <idno type="stamp" n="SUP_DRE" corresp="SUPELEC">DRE - Département de Recherche en Electromagnétisme</idno>
            <idno type="stamp" n="CENTRALESUPELEC">Ecole CentraleSupélec</idno>
            <idno type="stamp" n="GEEPS" corresp="SORBONNE-UNIVERSITE">Laboratoire Génie électrique et électronique de Paris</idno>
            <idno type="stamp" n="DRT" corresp="CEA">Direction de la recherche technologique</idno>
            <idno type="stamp" n="UNIV-PARIS-SACLAY">Université Paris-Saclay</idno>
            <idno type="stamp" n="UNIV-PSUD-SACLAY" corresp="UNIV-PARIS-SACLAY">Université Paris Sud pour Paris Saclay</idno>
            <idno type="stamp" n="UPMC_POLE_1" corresp="UPMC">UPMC Pôle 1</idno>
            <idno type="stamp" n="LIST" corresp="CEA">Laboratoire d'Intégration des Systèmes et des Technologies</idno>
            <idno type="stamp" n="SORBONNE-UNIVERSITE">Sorbonne Université</idno>
            <idno type="stamp" n="SU-SCIENCES" corresp="SORBONNE-UNIVERSITE">Faculté des Sciences de Sorbonne Université</idno>
            <idno type="stamp" n="GS-SPORT-HUMAN-MOVEMENT">Graduate School Sport, Mouvement, Facteurs Humains</idno>
            <idno type="stamp" n="ALLIANCE-SU"> Alliance Sorbonne Université</idno>
          </seriesStmt>
          <notesStmt>
            <note type="audience" n="2">International</note>
            <note type="popular" n="0">No</note>
          </notesStmt>
          <sourceDesc>
            <biblStruct>
              <analytic>
                <title xml:lang="en">Modelling of flawed riveted structures for EC inspection in aeronautics</title>
                <author role="aut">
                  <persName>
                    <forename type="first">S.</forename>
                    <surname>Paillard</surname>
                  </persName>
                  <email type="md5">9758f7ecb8ffa1e7c3510dceca110eb7</email>
                  <email type="domain">cea.fr</email>
                  <idno type="idhal" notation="string">severine-paillard</idno>
                  <idno type="idhal" notation="numeric">1356793</idno>
                  <idno type="halauthorid" notation="string">174020-1356793</idno>
                </author>
                <author role="aut">
                  <persName>
                    <forename type="first">G.</forename>
                    <surname>Pichenot</surname>
                  </persName>
                  <idno type="halauthorid">92064-0</idno>
                  <affiliation ref="#struct-40217"/>
                </author>
                <author role="aut">
                  <persName>
                    <forename type="first">Yahya</forename>
                    <surname>Choua</surname>
                  </persName>
                  <idno type="halauthorid">373625-0</idno>
                  <affiliation ref="#struct-1290"/>
                </author>
                <author role="aut">
                  <persName>
                    <forename type="first">Yann</forename>
                    <surname>Le Bihan</surname>
                  </persName>
                  <email type="md5">e84f86cd6222fa32dde9dc4de7a1ea66</email>
                  <email type="domain">geeps.centralesupelec.fr</email>
                  <idno type="idhal" notation="string">yann-le-bihan</idno>
                  <idno type="idhal" notation="numeric">6436</idno>
                  <idno type="halauthorid" notation="string">7402-6436</idno>
                  <idno type="IDREF">https://www.idref.fr/095667075</idno>
                  <idno type="ORCID">https://orcid.org/0000-0001-5563-9192</idno>
                  <affiliation ref="#struct-1290"/>
                </author>
                <author role="aut">
                  <persName>
                    <forename type="first">Marc</forename>
                    <surname>Lambert</surname>
                  </persName>
                  <email type="md5">6b1af8bef5ef916c396b6052bdff5219</email>
                  <email type="domain">geeps.centralesupelec.fr</email>
                  <idno type="idhal" notation="string">marc-lambert</idno>
                  <idno type="idhal" notation="numeric">2036</idno>
                  <idno type="halauthorid" notation="string">27088-2036</idno>
                  <idno type="ARXIV">https://arxiv.org/a/lambert_m_1</idno>
                  <idno type="RESEARCHERID">http://www.researcherid.com/rid/AAX-3271-2020</idno>
                  <idno type="IDREF">https://www.idref.fr/12429443X</idno>
                  <idno type="ORCID">https://orcid.org/0000-0003-0519-8477</idno>
                  <idno type="GOOGLE SCHOLAR">https://scholar.google.fr/citations?user=jx5l0-AAAAAJ&amp;hl=fr</idno>
                  <idno type="RESEARCHERID">http://www.researcherid.com/rid/http://www.researcherid.com/rid/AAX-3271-2020</idno>
                  <affiliation ref="#struct-396671"/>
                </author>
                <author role="aut">
                  <persName>
                    <forename type="first">Hubert</forename>
                    <surname>Voillaume</surname>
                  </persName>
                  <idno type="halauthorid">381947-0</idno>
                  <affiliation ref="#struct-88974"/>
                </author>
                <author role="aut">
                  <persName>
                    <forename type="first">N.</forename>
                    <surname>Dominguez</surname>
                  </persName>
                  <idno type="halauthorid">179941-0</idno>
                </author>
              </analytic>
              <monogr>
                <idno type="isbn">978-1-58603-896-0</idno>
                <title level="m">Electromagnetic Non–Destructive Evaluation</title>
                <editor>A. Tamburrino</editor>
                <editor>Y. Melikhov</editor>
                <editor>Z. Chen</editor>
                <editor>L. Upda</editor>
                <imprint>
                  <publisher>IOS Press</publisher>
                  <biblScope unit="serie">Studies in Applied Electromagnetics and Mechanics</biblScope>
                  <biblScope unit="volume">31</biblScope>
                  <biblScope unit="pp">217-224</biblScope>
                  <date type="datePub">2008</date>
                </imprint>
              </monogr>
              <idno type="doi">10.3233/978-1-58603-896-0-217</idno>
            </biblStruct>
          </sourceDesc>
          <profileDesc>
            <langUsage>
              <language ident="en">English</language>
            </langUsage>
            <textClass>
              <classCode scheme="halDomain" n="spi">Engineering Sciences [physics]</classCode>
              <classCode scheme="halTypology" n="COUV">Book sections</classCode>
              <classCode scheme="halOldTypology" n="COUV">Book sections</classCode>
              <classCode scheme="halTreeTypology" n="COUV">Book sections</classCode>
            </textClass>
            <abstract xml:lang="en">
              <p>Within the framework of a collaborative project between CEA and EADS, a semi-analytical model based on a Volume Integral Method (VIM) has been developed so as to simulate the Eddy Current (EC) inspection of riveted structures in aeronautics. The modeling is the one of a layered planar structure with a flaw located nearby a fastener. The VIM involving dyadic Green's functions is considered, a fastener and a flaw being introduced as a variation of conductivity in a stack of slabs. This semi-analytical approach is compared to a Finite-Element one (FE) developed by LGEP and is validated with experimental data acquired on an aeronautical configuration.</p>
            </abstract>
          </profileDesc>
        </biblFull>
      </listBibl>
    </body>
    <back>
      <listOrg type="structures">
        <org type="laboratory" xml:id="struct-40217" status="VALID">
          <idno type="IdRef">156836882</idno>
          <idno type="ISNI">0000 0004 0405 1788</idno>
          <idno type="RNSR">200118591H</idno>
          <idno type="ROR">https://ror.org/000dbcc61</idno>
          <idno type="Wikidata">Q30299467</idno>
          <orgName>Laboratoire d'Intégration des Systèmes et des Technologies</orgName>
          <orgName type="acronym">LIST (CEA)</orgName>
          <desc>
            <address>
              <addrLine>DRT/LISTNano-INNOVAvenue de la Vauve91120 Palaiseau</addrLine>
              <country key="FR"/>
            </address>
            <ref type="url">http://www-list.cea.fr/</ref>
          </desc>
          <listRelation>
            <relation name="DRT/LIST" active="#struct-440043" type="direct"/>
            <relation name="DRT" active="#struct-300016" type="indirect"/>
          </listRelation>
        </org>
        <org type="laboratory" xml:id="struct-1290" status="OLD">
          <orgName>Laboratoire de génie électrique de Paris</orgName>
          <orgName type="acronym">LGEP</orgName>
          <desc>
            <address>
              <addrLine>11 rue Joliot Curie Plateau de Moulon 91192 GIF SUR YVETTE CEDEX</addrLine>
              <country key="FR"/>
            </address>
            <ref type="url">http://www.lgep.supelec.fr</ref>
          </desc>
          <listRelation>
            <relation active="#struct-92966" type="direct"/>
            <relation active="#struct-93591" type="direct"/>
            <relation active="#struct-303397" type="direct"/>
            <relation name="UMR8507" active="#struct-441569" type="direct"/>
          </listRelation>
        </org>
        <org type="researchteam" xml:id="struct-396671" status="OLD">
          <orgName>DRE - Département de Recherche en Electromagnétisme ; EMG - Département Electromagnétisme - L2S</orgName>
          <desc>
            <address>
              <country key="FR"/>
            </address>
          </desc>
          <listRelation>
            <relation name="1289" active="#struct-1289" type="direct"/>
            <relation active="#struct-92966" type="indirect"/>
            <relation active="#struct-411575" type="indirect"/>
            <relation name="UMR8506" active="#struct-441569" type="indirect"/>
            <relation active="#struct-21400" type="direct"/>
            <relation name="300812" active="#struct-303397" type="indirect"/>
          </listRelation>
        </org>
        <org type="laboratory" xml:id="struct-88974" status="INCOMING">
          <orgName>EADS CCR - DCR/SE /IND</orgName>
          <desc>
            <address>
              <addrLine>12, rue Pasteur ? BP 76 92 152 Suresnes France</addrLine>
              <country key="FR"/>
            </address>
          </desc>
          <listRelation>
            <relation active="#struct-300780" type="direct"/>
          </listRelation>
        </org>
        <org type="regrouplaboratory" xml:id="struct-440043" status="VALID">
          <idno type="IdRef">067087930</idno>
          <idno type="ISNI">0000000121157881</idno>
          <idno type="RNSR">199018589D</idno>
          <idno type="ROR">https://ror.org/02ggzyd20</idno>
          <idno type="Wikidata">Q30299418</idno>
          <orgName>Direction de Recherche Technologique (CEA)</orgName>
          <orgName type="acronym">DRT (CEA)</orgName>
          <desc>
            <address>
              <country key="FR"/>
            </address>
            <ref type="url">http://www.drt-cea.com/</ref>
          </desc>
          <listRelation>
            <relation name="DRT" active="#struct-300016" type="direct"/>
          </listRelation>
        </org>
        <org type="institution" xml:id="struct-300016" status="VALID">
          <idno type="IdRef">026372061</idno>
          <idno type="ISNI">0000000122998025</idno>
          <idno type="ROR">https://ror.org/00jjx8s55</idno>
          <idno type="Wikidata">Q868550</idno>
          <orgName>Commissariat à l'énergie atomique et aux énergies alternatives</orgName>
          <orgName type="acronym">CEA</orgName>
          <desc>
            <address>
              <addrLine>Centre de SaclayCentre de GrenobleCentre de Cadaracheetc</addrLine>
              <country key="FR"/>
            </address>
            <ref type="url">http://www.cea.fr/</ref>
          </desc>
        </org>
        <org type="institution" xml:id="struct-92966" status="OLD">
          <idno type="ROR">https://ror.org/028rypz17</idno>
          <orgName>Université Paris-Sud - Paris 11</orgName>
          <orgName type="acronym">UP11</orgName>
          <date type="end">2019-12-31</date>
          <desc>
            <address>
              <addrLine>Bâtiment 300 - 91405 Orsay cedex</addrLine>
              <country key="FR"/>
            </address>
            <ref type="url">http://www.u-psud.fr/</ref>
          </desc>
        </org>
        <org type="institution" xml:id="struct-93591" status="OLD">
          <idno type="ROR">https://ror.org/02en5vm52</idno>
          <orgName>Université Pierre et Marie Curie - Paris 6</orgName>
          <orgName type="acronym">UPMC</orgName>
          <date type="end">2017-12-31</date>
          <desc>
            <address>
              <addrLine>4 place Jussieu - 75005 Paris</addrLine>
              <country key="FR"/>
            </address>
            <ref type="url">http://www.upmc.fr/</ref>
          </desc>
        </org>
        <org type="institution" xml:id="struct-303397" status="VALID">
          <orgName>Ecole Supérieure d'Electricité - SUPELEC (FRANCE)</orgName>
          <desc>
            <address>
              <country key="FR"/>
            </address>
          </desc>
        </org>
        <org type="regroupinstitution" xml:id="struct-441569" status="VALID">
          <idno type="IdRef">02636817X</idno>
          <idno type="ISNI">0000000122597504</idno>
          <idno type="ROR">https://ror.org/02feahw73</idno>
          <orgName>Centre National de la Recherche Scientifique</orgName>
          <orgName type="acronym">CNRS</orgName>
          <date type="start">1939-10-19</date>
          <desc>
            <address>
              <country key="FR"/>
            </address>
            <ref type="url">https://www.cnrs.fr/</ref>
          </desc>
        </org>
        <org type="laboratory" xml:id="struct-1289" status="OLD">
          <idno type="IdRef">133818799</idno>
          <idno type="RNSR">199812842X</idno>
          <orgName>Laboratoire des signaux et systèmes</orgName>
          <orgName type="acronym">L2S</orgName>
          <date type="end">2019-12-31</date>
          <desc>
            <address>
              <addrLine>Plateau de Moulon 3 rue Joliot Curie 91192 GIF SUR YVETTE CEDEX</addrLine>
              <country key="FR"/>
            </address>
            <ref type="url">http://www.l2s.centralesupelec.fr/</ref>
          </desc>
          <listRelation>
            <relation active="#struct-92966" type="direct"/>
            <relation active="#struct-411575" type="direct"/>
            <relation name="UMR8506" active="#struct-441569" type="direct"/>
          </listRelation>
        </org>
        <org type="institution" xml:id="struct-411575" status="VALID">
          <idno type="IdRef">184443237</idno>
          <idno type="ROR">https://ror.org/019tcpt25</idno>
          <orgName>CentraleSupélec</orgName>
          <desc>
            <address>
              <addrLine>3, rue Joliot Curie,Plateau de Moulon,91192 GIF-SUR-YVETTE Cedex</addrLine>
              <country key="FR"/>
            </address>
            <ref type="url">http://www.centralesupelec.fr</ref>
          </desc>
        </org>
        <org type="laboratory" xml:id="struct-21400" status="OLD">
          <orgName>SUPELEC-Campus Gif</orgName>
          <desc>
            <address>
              <addrLine>Plateau du Moulon - 3 rue Joliot-Curie - 91192 Gif-sur-Yvette CEDEX</addrLine>
              <country key="FR"/>
            </address>
            <ref type="url">http://www.supelec.fr/gif/</ref>
          </desc>
          <listRelation>
            <relation name="300812" active="#struct-303397" type="direct"/>
          </listRelation>
        </org>
        <org type="institution" xml:id="struct-300780" status="OLD">
          <orgName>EADS - European Aeronautic Defense and Space</orgName>
          <desc>
            <address>
              <country key="FR"/>
            </address>
          </desc>
        </org>
      </listOrg>
    </back>
  </text>
</TEI>