<?xml version="1.0" encoding="utf-8"?>
<TEI xmlns="http://www.tei-c.org/ns/1.0" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:hal="http://hal.archives-ouvertes.fr/" xmlns:gml="http://www.opengis.net/gml/3.3/" xmlns:gmlce="http://www.opengis.net/gml/3.3/ce" version="1.1" xsi:schemaLocation="http://www.tei-c.org/ns/1.0 http://api.archives-ouvertes.fr/documents/aofr-sword.xsd">
  <teiHeader>
    <fileDesc>
      <titleStmt>
        <title>HAL TEI export of hal-01639241</title>
      </titleStmt>
      <publicationStmt>
        <distributor>CCSD</distributor>
        <availability status="restricted">
          <licence target="https://creativecommons.org/publicdomain/zero/1.0/">CC0 1.0 - Universal</licence>
        </availability>
        <date when="2026-05-24T22:58:36+02:00"/>
      </publicationStmt>
      <sourceDesc>
        <p part="N">HAL API Platform</p>
      </sourceDesc>
    </fileDesc>
  </teiHeader>
  <text>
    <body>
      <listBibl>
        <biblFull>
          <titleStmt>
            <title xml:lang="en">A Statistical Study of DORT Method for Locating Soft Faults in Complex Wire Networks</title>
            <author role="aut">
              <persName>
                <forename type="first">Moussa</forename>
                <surname>Kafal</surname>
              </persName>
              <idno type="halauthorid">942994-0</idno>
              <orgName ref="#struct-300016"/>
              <affiliation ref="#struct-577943"/>
            </author>
            <author role="aut">
              <persName>
                <forename type="first">Jaume</forename>
                <surname>Benoit</surname>
              </persName>
              <idno type="halauthorid">1373694-0</idno>
              <orgName ref="#struct-300016"/>
              <affiliation ref="#struct-577943"/>
            </author>
            <author role="aut">
              <persName>
                <forename type="first">Andréa</forename>
                <surname>Cozza</surname>
              </persName>
              <email type="md5">dd5d1cc9e510aed631770db8f0af7deb</email>
              <email type="domain">centralesupelec.fr</email>
              <idno type="idhal" notation="string">andrea-cozza</idno>
              <idno type="idhal" notation="numeric">8868</idno>
              <idno type="halauthorid" notation="string">20318-8868</idno>
              <idno type="ORCID">https://orcid.org/0000-0002-1317-6684</idno>
              <idno type="GOOGLE SCHOLAR">https://scholar.google.fr/citations?user=dKy3eGYAAAAJ&amp;hl=fr</idno>
              <idno type="IDREF">https://www.idref.fr/090944658</idno>
              <affiliation ref="#struct-411302"/>
            </author>
            <author role="aut">
              <persName>
                <forename type="first">Lionel</forename>
                <surname>Pichon</surname>
              </persName>
              <email type="md5">d071d3152610a95aad08c1c629bca75e</email>
              <email type="domain">geeps.centralesupelec.fr</email>
              <idno type="idhal" notation="string">lionel-pichon</idno>
              <idno type="idhal" notation="numeric">6078</idno>
              <idno type="halauthorid" notation="string">7403-6078</idno>
              <idno type="RESEARCHERID">http://www.researcherid.com/rid/ABI-2372-2020</idno>
              <idno type="ORCID">https://orcid.org/0000-0002-3402-5498</idno>
              <idno type="IDREF">https://www.idref.fr/076470679</idno>
              <idno type="RESEARCHERID">http://www.researcherid.com/rid/http://www.researcherid.com/rid/ABI-2372-2020</idno>
              <affiliation ref="#struct-411302"/>
            </author>
            <editor role="depositor">
              <persName>
                <forename>Andrea</forename>
                <surname>Cozza</surname>
              </persName>
              <email type="md5">dd5d1cc9e510aed631770db8f0af7deb</email>
              <email type="domain">centralesupelec.fr</email>
            </editor>
          </titleStmt>
          <editionStmt>
            <edition n="v1" type="current">
              <date type="whenSubmitted">2017-11-20 13:13:44</date>
              <date type="whenModified">2025-09-24 18:49:18</date>
              <date type="whenReleased">2017-11-22 10:50:48</date>
              <date type="whenProduced">2018-03</date>
              <date type="whenEndEmbargoed">2017-11-20</date>
              <ref type="file" target="https://centralesupelec.hal.science/hal-01639241v1/document">
                <date notBefore="2017-11-20"/>
              </ref>
              <ref type="file" subtype="author" n="1" target="https://centralesupelec.hal.science/hal-01639241v1/file/08107704.pdf" id="file-1639373-1686866">
                <date notBefore="2017-11-20"/>
              </ref>
              <ref type="externalLink" target="https://hal-centralesupelec.archives-ouvertes.fr/hal-01639241/file/08107704.pdf"/>
            </edition>
            <respStmt>
              <resp>contributor</resp>
              <name key="146215">
                <persName>
                  <forename>Andrea</forename>
                  <surname>Cozza</surname>
                </persName>
                <email type="md5">dd5d1cc9e510aed631770db8f0af7deb</email>
                <email type="domain">centralesupelec.fr</email>
              </name>
            </respStmt>
          </editionStmt>
          <publicationStmt>
            <distributor>CCSD</distributor>
            <idno type="halId">hal-01639241</idno>
            <idno type="halUri">https://centralesupelec.hal.science/hal-01639241</idno>
            <idno type="halBibtex">kafal:hal-01639241</idno>
            <idno type="halRefHtml">&lt;i&gt;IEEE Transactions on Magnetics&lt;/i&gt;, 2018, 54 (3), pp.8700304. &lt;a target="_blank" href="https://dx.doi.org/10.1109/TMAG.2017.2765463"&gt;&amp;#x27E8;10.1109/TMAG.2017.2765463&amp;#x27E9;&lt;/a&gt;</idno>
            <idno type="halRef">IEEE Transactions on Magnetics, 2018, 54 (3), pp.8700304. &amp;#x27E8;10.1109/TMAG.2017.2765463&amp;#x27E9;</idno>
            <availability status="restricted">
              <licence target="https://about.hal.science/hal-authorisation-v1/">HAL Authorization<ref corresp="#file-1639373-1686866"/></licence>
            </availability>
          </publicationStmt>
          <seriesStmt>
            <idno type="stamp" n="CEA">CEA - Commissariat à l'énergie atomique</idno>
            <idno type="stamp" n="UPMC" corresp="SORBONNE-UNIVERSITE">Université Pierre et Marie Curie</idno>
            <idno type="stamp" n="CNRS">CNRS - Centre national de la recherche scientifique</idno>
            <idno type="stamp" n="UNIV-PSUD">Université Paris Sud - Paris XI</idno>
            <idno type="stamp" n="CENTRALESUPELEC">Ecole CentraleSupélec</idno>
            <idno type="stamp" n="GEEPS" corresp="SORBONNE-UNIVERSITE">Laboratoire Génie électrique et électronique de Paris</idno>
            <idno type="stamp" n="PIEM" corresp="GEEPS">Pôle Electromagnétisme</idno>
            <idno type="stamp" n="DRT" corresp="CEA">Direction de la recherche technologique</idno>
            <idno type="stamp" n="CEA-UPSAY" corresp="CEA">CEA - Université Paris-Saclay</idno>
            <idno type="stamp" n="UNIV-PARIS-SACLAY">Université Paris-Saclay</idno>
            <idno type="stamp" n="UNIV-PSUD-SACLAY" corresp="UNIV-PARIS-SACLAY">Université Paris Sud pour Paris Saclay</idno>
            <idno type="stamp" n="CEA-UPSAY-SACLAY" corresp="CEA">CEA-UPSAY-SACLAY</idno>
            <idno type="stamp" n="CENTRALESUPELEC-SACLAY" corresp="UNIV-PARIS-SACLAY">CENTRALESUPELEC-SACLAY</idno>
            <idno type="stamp" n="LIST" corresp="CEA">Laboratoire d'Intégration des Systèmes et des Technologies</idno>
            <idno type="stamp" n="SORBONNE-UNIVERSITE">Sorbonne Université</idno>
            <idno type="stamp" n="SORBONNE-UNIV" corresp="SORBONNE-UNIVERSITE">Sorbonne Université 01/01/2018</idno>
            <idno type="stamp" n="SU-SCIENCES" corresp="SORBONNE-UNIVERSITE">Faculté des Sciences de Sorbonne Université</idno>
            <idno type="stamp" n="DM2I" corresp="LIST">Département Métrologie Instrumentation &amp; Information</idno>
            <idno type="stamp" n="TEST-HALCNRS">Collection test HAL CNRS</idno>
            <idno type="stamp" n="GEEPS-ELECTRONIQUE">Equipe Electronique du GeePs</idno>
            <idno type="stamp" n="SU-TI">Sorbonne Université - Texte Intégral</idno>
            <idno type="stamp" n="GS-ENGINEERING">Graduate School Sciences de l'Ingénierie et des Systèmes</idno>
            <idno type="stamp" n="GS-COMPUTER-SCIENCE">Graduate School Computer Science</idno>
            <idno type="stamp" n="GS-PHYSIQUE">Graduate School Physique</idno>
            <idno type="stamp" n="GS-SPORT-HUMAN-MOVEMENT">Graduate School Sport, Mouvement, Facteurs Humains</idno>
            <idno type="stamp" n="INSTITUT-SCIENCES-LUMIERE">Institut des Sciences de la Lumière</idno>
            <idno type="stamp" n="ALLIANCE-SU"> Alliance Sorbonne Université</idno>
            <idno type="stamp" n="DIN" corresp="DRT">Département d'Instrumentation Numérique</idno>
            <idno type="stamp" n="SUPRA_INGENIERIE">Ingénierie</idno>
          </seriesStmt>
          <notesStmt>
            <note type="audience" n="2">International</note>
            <note type="popular" n="0">No</note>
            <note type="peer" n="1">Yes</note>
          </notesStmt>
          <sourceDesc>
            <biblStruct>
              <analytic>
                <title xml:lang="en">A Statistical Study of DORT Method for Locating Soft Faults in Complex Wire Networks</title>
                <author role="aut">
                  <persName>
                    <forename type="first">Moussa</forename>
                    <surname>Kafal</surname>
                  </persName>
                  <idno type="halauthorid">942994-0</idno>
                  <orgName ref="#struct-300016"/>
                  <affiliation ref="#struct-577943"/>
                </author>
                <author role="aut">
                  <persName>
                    <forename type="first">Jaume</forename>
                    <surname>Benoit</surname>
                  </persName>
                  <idno type="halauthorid">1373694-0</idno>
                  <orgName ref="#struct-300016"/>
                  <affiliation ref="#struct-577943"/>
                </author>
                <author role="aut">
                  <persName>
                    <forename type="first">Andréa</forename>
                    <surname>Cozza</surname>
                  </persName>
                  <email type="md5">dd5d1cc9e510aed631770db8f0af7deb</email>
                  <email type="domain">centralesupelec.fr</email>
                  <idno type="idhal" notation="string">andrea-cozza</idno>
                  <idno type="idhal" notation="numeric">8868</idno>
                  <idno type="halauthorid" notation="string">20318-8868</idno>
                  <idno type="ORCID">https://orcid.org/0000-0002-1317-6684</idno>
                  <idno type="GOOGLE SCHOLAR">https://scholar.google.fr/citations?user=dKy3eGYAAAAJ&amp;hl=fr</idno>
                  <idno type="IDREF">https://www.idref.fr/090944658</idno>
                  <affiliation ref="#struct-411302"/>
                </author>
                <author role="aut">
                  <persName>
                    <forename type="first">Lionel</forename>
                    <surname>Pichon</surname>
                  </persName>
                  <email type="md5">d071d3152610a95aad08c1c629bca75e</email>
                  <email type="domain">geeps.centralesupelec.fr</email>
                  <idno type="idhal" notation="string">lionel-pichon</idno>
                  <idno type="idhal" notation="numeric">6078</idno>
                  <idno type="halauthorid" notation="string">7403-6078</idno>
                  <idno type="RESEARCHERID">http://www.researcherid.com/rid/ABI-2372-2020</idno>
                  <idno type="ORCID">https://orcid.org/0000-0002-3402-5498</idno>
                  <idno type="IDREF">https://www.idref.fr/076470679</idno>
                  <idno type="RESEARCHERID">http://www.researcherid.com/rid/http://www.researcherid.com/rid/ABI-2372-2020</idno>
                  <affiliation ref="#struct-411302"/>
                </author>
              </analytic>
              <monogr>
                <idno type="halJournalId" status="VALID">14060</idno>
                <idno type="issn">0018-9464</idno>
                <idno type="eissn">1941-0069</idno>
                <title level="j">IEEE Transactions on Magnetics</title>
                <imprint>
                  <publisher>Institute of Electrical and Electronics Engineers</publisher>
                  <biblScope unit="volume">54</biblScope>
                  <biblScope unit="issue">3</biblScope>
                  <biblScope unit="pp">8700304</biblScope>
                  <date type="datePub">2018-03</date>
                  <date type="dateEpub">2017-11-14</date>
                </imprint>
              </monogr>
              <idno type="doi">10.1109/TMAG.2017.2765463</idno>
              <ref type="publisher">https://ieeexplore.ieee.org/document/8107704</ref>
            </biblStruct>
          </sourceDesc>
          <profileDesc>
            <langUsage>
              <language ident="en">English</language>
            </langUsage>
            <textClass>
              <keywords scheme="author">
                <term xml:lang="en">transmission lines</term>
                <term xml:lang="en">DORT technique</term>
                <term xml:lang="en">time-reversal operator</term>
                <term xml:lang="en">Decomposition of the time-reversal operator (DORT)</term>
                <term xml:lang="en">defect</term>
                <term xml:lang="en">Transferometry</term>
                <term xml:lang="en">Reflectometry</term>
                <term xml:lang="en">diagnosis</term>
                <term xml:lang="en">cable</term>
                <term xml:lang="en">statistical analysis</term>
                <term xml:lang="en">power transmission lines</term>
                <term xml:lang="en">Junctions</term>
                <term xml:lang="en">complex wire networks</term>
                <term xml:lang="en">real-life networks</term>
                <term xml:lang="en">Wires</term>
                <term xml:lang="en">Ports (Computers)</term>
                <term xml:lang="en">power transmission fault</term>
                <term xml:lang="en">Fault location</term>
                <term xml:lang="en">Circuit fault</term>
                <term xml:lang="en">Testing</term>
              </keywords>
              <classCode scheme="halDomain" n="spi.elec">Engineering Sciences [physics]/Electromagnetism</classCode>
              <classCode scheme="halTypology" n="ART">Journal articles</classCode>
              <classCode scheme="halOldTypology" n="ART">Journal articles</classCode>
              <classCode scheme="halTreeTypology" n="ART">Journal articles</classCode>
            </textClass>
            <abstract xml:lang="en">
              <p>Decomposition of the time-reversal (TR) operator (DORT), a recently applied TR method to transmission lines, has proven to be effective in detecting and locating soft faults in complex wire networks. In this paper, we will propose a fault location criterion which will form a later basis for a statistical study investigating the influence of several parameters, namely, the number of testing ports and the position of the fault, on the performance of DORT technique. Notably, this would allow a closer inspection of the method's practicability for future implementation in real-life networks. Index Terms— Complex wire networks, decomposition of the time-reversal (TR) operator (DORT) method, soft fault location, statistical study.</p>
            </abstract>
          </profileDesc>
        </biblFull>
      </listBibl>
    </body>
    <back>
      <listOrg type="structures">
        <org type="researchteam" xml:id="struct-577943" status="OLD">
          <orgName>Laboratoire Fiabilité et Intégration de Capteurs (CEA, LIST)</orgName>
          <orgName type="acronym">LFIC (CEA, LIST)</orgName>
          <date type="start">2020-01-01</date>
          <date type="end">2022-12-31</date>
          <desc>
            <address>
              <country key="FR"/>
            </address>
          </desc>
          <listRelation>
            <relation name="DRT/LIST/DM2I/SCI/LFIC" active="#struct-528161" type="direct"/>
            <relation name="DRT/LIST/DM2I" active="#struct-40217" type="indirect"/>
            <relation name="DRT/LIST" active="#struct-440043" type="indirect"/>
            <relation name="DRT" active="#struct-300016" type="indirect"/>
            <relation active="#struct-419361" type="indirect"/>
          </listRelation>
        </org>
        <org type="laboratory" xml:id="struct-411302" status="OLD">
          <idno type="IdRef">152859241</idno>
          <idno type="RNSR">199812843Y</idno>
          <orgName>Laboratoire Génie électrique et électronique de Paris</orgName>
          <orgName type="acronym">GeePs</orgName>
          <date type="start">2015-01-01</date>
          <date type="end">2018-12-31</date>
          <desc>
            <address>
              <addrLine>11, rue Joliot CuriePlateau de Moulon91192 Gif sur Yvette</addrLine>
              <country key="FR"/>
            </address>
            <ref type="url">http://geeps.lgep.supelec.fr/</ref>
          </desc>
          <listRelation>
            <relation active="#struct-92966" type="direct"/>
            <relation active="#struct-93591" type="direct"/>
            <relation active="#struct-411575" type="direct"/>
            <relation name="UMR8507" active="#struct-441569" type="direct"/>
          </listRelation>
        </org>
        <org type="department" xml:id="struct-528161" status="OLD">
          <idno type="RNSR">200822621H</idno>
          <orgName>Département Métrologie Instrumentation &amp; Information (CEA, LIST)</orgName>
          <orgName type="acronym">DM2I (CEA, LIST)</orgName>
          <date type="start">2013-04-01</date>
          <date type="end">2022-12-31</date>
          <desc>
            <address>
              <addrLine>ex DCSI.ex DETECS.CEA LIST</addrLine>
              <country key="FR"/>
            </address>
          </desc>
          <listRelation>
            <relation name="DRT/LIST/DM2I" active="#struct-40217" type="direct"/>
            <relation name="DRT/LIST" active="#struct-440043" type="indirect"/>
            <relation name="DRT" active="#struct-300016" type="indirect"/>
            <relation active="#struct-419361" type="direct"/>
          </listRelation>
        </org>
        <org type="laboratory" xml:id="struct-40217" status="VALID">
          <idno type="IdRef">156836882</idno>
          <idno type="ISNI">0000 0004 0405 1788</idno>
          <idno type="RNSR">200118591H</idno>
          <idno type="ROR">https://ror.org/000dbcc61</idno>
          <idno type="Wikidata">Q30299467</idno>
          <orgName>Laboratoire d'Intégration des Systèmes et des Technologies</orgName>
          <orgName type="acronym">LIST (CEA)</orgName>
          <desc>
            <address>
              <addrLine>DRT/LISTNano-INNOVAvenue de la Vauve91120 Palaiseau</addrLine>
              <country key="FR"/>
            </address>
            <ref type="url">http://www-list.cea.fr/</ref>
          </desc>
          <listRelation>
            <relation name="DRT/LIST" active="#struct-440043" type="direct"/>
            <relation name="DRT" active="#struct-300016" type="indirect"/>
          </listRelation>
        </org>
        <org type="regrouplaboratory" xml:id="struct-440043" status="VALID">
          <idno type="IdRef">067087930</idno>
          <idno type="ISNI">0000000121157881</idno>
          <idno type="RNSR">199018589D</idno>
          <idno type="ROR">https://ror.org/02ggzyd20</idno>
          <idno type="Wikidata">Q30299418</idno>
          <orgName>Direction de Recherche Technologique (CEA)</orgName>
          <orgName type="acronym">DRT (CEA)</orgName>
          <desc>
            <address>
              <country key="FR"/>
            </address>
            <ref type="url">http://www.drt-cea.com/</ref>
          </desc>
          <listRelation>
            <relation name="DRT" active="#struct-300016" type="direct"/>
          </listRelation>
        </org>
        <org type="institution" xml:id="struct-300016" status="VALID">
          <idno type="IdRef">026372061</idno>
          <idno type="ISNI">0000000122998025</idno>
          <idno type="ROR">https://ror.org/00jjx8s55</idno>
          <idno type="Wikidata">Q868550</idno>
          <orgName>Commissariat à l'énergie atomique et aux énergies alternatives</orgName>
          <orgName type="acronym">CEA</orgName>
          <desc>
            <address>
              <addrLine>Centre de SaclayCentre de GrenobleCentre de Cadaracheetc</addrLine>
              <country key="FR"/>
            </address>
            <ref type="url">http://www.cea.fr/</ref>
          </desc>
        </org>
        <org type="institution" xml:id="struct-419361" status="VALID">
          <idno type="IdRef">241345251</idno>
          <idno type="ROR">https://ror.org/03xjwb503</idno>
          <orgName>Université Paris-Saclay</orgName>
          <desc>
            <address>
              <addrLine>Bâtiment Bréguet, 3 Rue Joliot Curie 2e ét, 91190 Gif-sur-Yvette</addrLine>
              <country key="FR"/>
            </address>
            <ref type="url">https://www.universite-paris-saclay.fr/fr</ref>
          </desc>
        </org>
        <org type="institution" xml:id="struct-92966" status="OLD">
          <idno type="ROR">https://ror.org/028rypz17</idno>
          <orgName>Université Paris-Sud - Paris 11</orgName>
          <orgName type="acronym">UP11</orgName>
          <date type="end">2019-12-31</date>
          <desc>
            <address>
              <addrLine>Bâtiment 300 - 91405 Orsay cedex</addrLine>
              <country key="FR"/>
            </address>
            <ref type="url">http://www.u-psud.fr/</ref>
          </desc>
        </org>
        <org type="institution" xml:id="struct-93591" status="OLD">
          <idno type="ROR">https://ror.org/02en5vm52</idno>
          <orgName>Université Pierre et Marie Curie - Paris 6</orgName>
          <orgName type="acronym">UPMC</orgName>
          <date type="end">2017-12-31</date>
          <desc>
            <address>
              <addrLine>4 place Jussieu - 75005 Paris</addrLine>
              <country key="FR"/>
            </address>
            <ref type="url">http://www.upmc.fr/</ref>
          </desc>
        </org>
        <org type="institution" xml:id="struct-411575" status="VALID">
          <idno type="IdRef">184443237</idno>
          <idno type="ROR">https://ror.org/019tcpt25</idno>
          <orgName>CentraleSupélec</orgName>
          <desc>
            <address>
              <addrLine>3, rue Joliot Curie,Plateau de Moulon,91192 GIF-SUR-YVETTE Cedex</addrLine>
              <country key="FR"/>
            </address>
            <ref type="url">http://www.centralesupelec.fr</ref>
          </desc>
        </org>
        <org type="regroupinstitution" xml:id="struct-441569" status="VALID">
          <idno type="IdRef">02636817X</idno>
          <idno type="ISNI">0000000122597504</idno>
          <idno type="ROR">https://ror.org/02feahw73</idno>
          <orgName>Centre National de la Recherche Scientifique</orgName>
          <orgName type="acronym">CNRS</orgName>
          <date type="start">1939-10-19</date>
          <desc>
            <address>
              <country key="FR"/>
            </address>
            <ref type="url">https://www.cnrs.fr/</ref>
          </desc>
        </org>
      </listOrg>
    </back>
  </text>
</TEI>