A Statistical Study of DORT Method for Locating Soft Faults in Complex Wire Networks - CentraleSupélec Access content directly
Journal Articles IEEE Transactions on Magnetics Year : 2018

A Statistical Study of DORT Method for Locating Soft Faults in Complex Wire Networks

Abstract

Decomposition of the time-reversal (TR) operator (DORT), a recently applied TR method to transmission lines, has proven to be effective in detecting and locating soft faults in complex wire networks. In this paper, we will propose a fault location criterion which will form a later basis for a statistical study investigating the influence of several parameters, namely, the number of testing ports and the position of the fault, on the performance of DORT technique. Notably, this would allow a closer inspection of the method's practicability for future implementation in real-life networks. Index Terms— Complex wire networks, decomposition of the time-reversal (TR) operator (DORT) method, soft fault location, statistical study.
Fichier principal
Vignette du fichier
08107704.pdf (816.66 Ko) Télécharger le fichier
Origin Files produced by the author(s)
Loading...

Dates and versions

hal-01639241 , version 1 (20-11-2017)

Identifiers

Cite

Moussa Kafal, Jaume Benoit, Andréa Cozza, Lionel Pichon. A Statistical Study of DORT Method for Locating Soft Faults in Complex Wire Networks. IEEE Transactions on Magnetics, 2018, 54 (3), pp.8700304. ⟨10.1109/TMAG.2017.2765463⟩. ⟨hal-01639241⟩